What Are Heat Loss Calculations?
Heat loss calculations are performed after a heat loss survey on a property and help understand the heating needs of the property by calculating the heat loss of the properties fabric. Heat loss calculations help an installer understand how much heat the building will loose through though the year.
This calculation is essential for installing the right size heat pump and getting the correct radiators sizing for the property. Having accurate heat loss calculations performed will ensure the efficiency of the system design and prolong the life of the product by making sure the system is not under or over sized putting strain on the system.
Why Use Apex For Your Heat Loss Calculations in Oxfordshire?
Alongside the technical surveyors, we have a full time, in-house design team with a collective 30+ years of experience in designing heating systems and performing heat loss calculations. Apex Renewable Energy Surveys started in Doncaster which is based in Yorkshire.
Working to the standards and methodology set out in MCS3005-D and the CIBSE Domestic Heating Guide, our service includes:
-
Complete room-by-room heat loss calculations for the full property
-
A detailed heat loss summary
-
Required emitters with outputs at the required flow temperature
-
Details of the proposed equipment (such as SCoP, maximum output, etc)
-
MCS035 Model Performance Estimation
-
MCS020 Sound Calculations
-
Recommended equipment
-
Any site-specific recommendations
As an optional extra, alongside the heat loss calculation, our design team can also provide a completed DNO application form with the relevant unit-specific technical information and assist you with the application process, saving you time with your pre-installation administration.
Our Air Source Heat Loss Calculation Achievements
Heat Loss Calcs
Completed
0
Mw of Heat Loss
Calculated
0
Radiators
Designed
0
MCS Documents
Produced
0
Versions of Our in
House Calculator
0
Understanding Radiator Sizing and Heat Loss Calculations in Oxfordshire
As part of air source heat pump survey we also provide the full measurements of existing radiators and the room available for future changes. Apex Renewable Energy Surveys understand the importance of sizing radiators correctly with air source heat pumps and our professionally trained office staff specialise in heat loss calculations. This allows them to accurate calculate the correct radiators needed for the designed flow temperature of the ASHP that has been selected for the job.
Key Benefits of Heat Loss Calculations Done by Apex
MCS and DNO Documentation
We provide MCS and DNO documents on our jobs to help alleviate your admin work and process's within in your office making a smoother process for your customers.
You will receive a full radiator schedule stating which radiators need to be replaced what that radiators you need to replace them with.
Air Source Heat Pump Floor Plans in Oxfordshire
Apex Renewable Energy Surveys will also provide a full floor plan after each survey, giving you a far easier job of planning your new potential installation. Not only does the floor plan make planning the installation run a lot smoother but it allows better communication between you and your customer. The customer will be able to understand which room you are discussing with them at any point, bedroom 1 and bedroom 2 can start to get confusing at some points in discussions with a floor plan guide this can happen much easier. This also allows installers to understand where the radiators are located and the basic information of the cylinder and current boiler locations.
Heat Loss Calculation Costs in Oxfordshire
Heat loss calculations are very admin heavy and require a lot of knowledge and expertise this can often put up hurdles for new companies or growing companies. Apex Renewable Energy Surveys already have a fully professional established team with years of experience to perform heat loss calculations in a timely manor while making sure the accuracy is kept to high standard. We have built our costing system for heat loss calculations to allow companies a competitive price while also removing the leg work involved.
Increase Sale Conversion Rates in Oxfordshire
Not only do Apex Renewable Energy Surveys provide professional and accurate surveys but we also get very positive reports from existing installers that we have increased sales conversion rates. This is due to many factors but the main factor for you as installer is that you can explain to your customer that a third party surveying company will be performing the survey. When explained properly this is a massive win for the customer as they will have the trust knowing that a fully experienced professional surveying company will be gathering the information and providing the system design giving them peace of mind that the system will be designed to the property and not to the installers benefit.
Importance of Heat Loss Calculations in Oxfordshire
Heat loss calculations are essential for the effective installation and performance of heat pumps in Oxfordshire, ensuring that homes are heated efficiently while reducing energy costs and carbon emissions. With the availability of the £7,500 Boiler Upgrade Scheme (BUS) voucher, homeowners have a compelling reason to consider heat pumps as an eco-friendly heating option. Accurate heat loss calculations are critical for maximizing these benefits.
Key Reasons for Heat Loss Calculations in Oxfordshire:
-
Accurate Heat Pump Sizing
Heat loss calculations determine the correct size of the heat pump for the property. An undersized heat pump may fail to keep the home warm, while an oversized system could waste energy and increase running costs. -
Energy Efficiency
By identifying how much heat escapes from the property, heat loss calculations enable the design of a highly efficient system, minimizing energy consumption and reducing utility bills for homeowners in Oxfordshire. -
Adaptation to Oxfordshire’s Climate
Oxfordshire’s mix of rural and urban environments, with colder winter temperatures, requires heating systems to be adapted to local conditions. Heat loss calculations ensure heat pumps are capable of providing sufficient warmth throughout the year. -
Eligibility for the £7,500 Boiler Upgrade Scheme
The £7,500 BUS voucher is a valuable incentive for Oxfordshire homeowners switching to heat pumps. Meeting energy efficiency standards through accurate heat loss calculations is often necessary to qualify for this financial support. -
Lower Energy Bills
A heat pump sized using precise heat loss data will operate more cost-effectively. Oxfordshire residents can enjoy significant savings compared to traditional heating systems powered by gas or oil. -
Reducing Carbon Footprints
Heat pumps rely on renewable energy sources and produce fewer carbon emissions. Accurate heat loss calculations optimize the system’s performance, further reducing environmental impact and contributing to Oxfordshire’s sustainability goals. -
Enhanced Home Comfort
Accurate heat loss assessments help maintain consistent temperatures across the property. This ensures a more comfortable living environment, particularly during Oxfordshire’s colder months. -
Compliance with Building Regulations
Heat pump installations must adhere to UK Building Regulations for energy efficiency. Heat loss calculations ensure installations in Oxfordshire meet these legal requirements, avoiding potential compliance issues. -
Optimized Heat Distribution
Heat loss calculations guide the design of effective heat distribution systems, such as underfloor heating or radiators. This prevents cold spots and ensures the entire home is heated efficiently. -
Tailoring to Property Types
Oxfordshire is home to a diverse range of properties, from historic cottages to modern homes. Heat loss calculations account for variations in insulation, building materials, and glazing to provide tailored solutions for each property type. -
Supporting Local Sustainability Goals
Oxfordshire has a strong focus on environmental sustainability. Accurate heat loss calculations ensure heat pumps operate efficiently, reducing reliance on fossil fuels and helping meet local climate targets. -
Maximizing the Boiler Upgrade Scheme’s Value
The £7,500 BUS voucher makes heat pumps more accessible for Oxfordshire homeowners. Accurate heat loss calculations ensure systems are efficient and cost-effective, maximizing the return on investment from this incentive.
Conclusion
In Oxfordshire, heat loss calculations are a critical component of heat pump installations. They ensure systems are designed to meet local climate challenges and property requirements, improving energy efficiency, reducing carbon emissions, and enhancing home comfort. With the support of the £7,500 Boiler Upgrade Scheme, accurate heat loss assessments are key to making heat pumps an affordable and sustainable heating solution in Oxfordshire.
Heat Loss Calculation Locations in Oxfordshire
We have the largest network of fully qualified and experienced Domestic Energy Assessors (DEA's) in the country, allowing us to easily access around 95% of the country, including off-grid towns across the north and east of England and Wales.
We have extensive coverage in:
For areas not listed, please contact our admin team who will be happy to find a solution.
Abingdon
Adderbury
Appleford
Ashbury
Bampton
Banbury
Benson
Bicester
Bloxham
Botley
Brightwell Baldwin
Burford
Carterton
Chadlington
Chalgrove
Charlbury
Checkendon
Chinnor
Chipping Norton
Cholsey
Didcot
Enstone
Eynsham
Faringdon
Fifield
Garsington
Goring
Harwell
Henley-on-Thames
Hook Norton
Horspath
Kiddington
Kidlington
Kingham
Kirtlington
Long Hanborough
Middle Barton
Milton
Oxford
Shrivenham
South Stoke
Stanton Harcourt
Steeple Aston
Steventon
Summertown
Sydenham
Thame
Wallingford
Wantage
Watlington
Weston-on-the-Green
Wheatley
Witney
Woodstock
Wroxton
How to Get Started with Our Heat Loss Survey
0333 577 2452 (Booking Line)
Apex Surveys
2c Kings Mews
Doncaster
DN1 1JD
Mon 09:00 - 17:00
Tue 09:00 - 17:00
Wed 09:00 - 17:00
Thu 09:00 - 17:00
Fri 09:00 - 16:00
Sat Booking Line Only
Sun Booking Line Only
You can also reach our team using the contact form below: